All technology
HERZIOX POWER

Energy storage and management.

Storage adapted to your facility for backup, power management and a more flexible energy strategy.

Request an assessment
Illustration of HERZIOX POWER with a storage container and two cabinets.
FunctionEnergy storage
ConfigurationCabinets and containers
SizingFacility-specific

Store energy with a clear purpose

Storage can support backup, power management or the integration of on-site generation. The starting point is to decide what your facility needs.

HERZIOX POWER is sized around the consumption profile, available sources and intended use. Storage, generation and consumption can then be considered as parts of one energy strategy.

The P261 and S261-AC cabinets and the S1044-AC and S2170-AC containers can be sized to manage demand peaks, use surplus generation on site and provide backup. The P4888 and P5015 containers are assessed for large-scale storage, renewable generation integration, grid services and arbitrage.

Energy storage cabinets

P261
261.96 kWh nominal capacity · 125 kW nominal power · Integrated cabinet
S261-AC
261.2 kWh nominal capacity · 125 kW nominal power · AC-coupled cabinet

Energy storage containers

S1044-AC
1,044 kWh nominal capacity · 500 kVA nominal power · Compact outdoor AC-coupled container
S2170-AC
2,170 kWh nominal capacity · 1,000 kVA nominal power · 20-foot AC-coupled container
P4888
4,888 kWh nominal capacity · 2,400 kW maximum charge and discharge power · 20-foot container
P5015
5,015.09 kWh nominal capacity · 2,500 kW maximum charge and discharge power · 20-foot container

Power, capacity and operating strategy

Power determines the demand the system can serve; capacity affects how long it can do so. Sizing considers consumption profiles, generation, charging and discharging windows and backup reserve. Autonomy and savings are calculated for a defined scenario, including losses and constraints.

Nominal capacity describes how much energy the system can store and is expressed in kWh or MWh. One MWh equals 1,000 kWh. kW measures active power and kVA measures apparent power. Compare nominal and maximum power ratings separately.

Alongside backup power, self-consumption and peak demand management, we assess how to manage power and shift energy purchases or use through day-ahead and intraday arbitrage.

Day-ahead and intraday arbitrage shifts energy purchases or use between periods with different costs. Secondary regulation (aFRR) responds automatically to a balancing signal. Tertiary regulation (mFRR) is activated at the operator’s instruction.

Spain’s active demand response service (SRAD) is based on reducing flexible demand. To assess participation, we check the configuration of the facility, its metering and access requirements. Additional battery discharge cannot by itself replace that reduction in demand.

Before combining applications, we check their compatibility and preserve the energy and power reserve needed for continuity. Market revenue depends on participation and market conditions. Savings are calculated separately from facility data.

How we assess arbitrage and flexibility

Information to prepare

Share the available electrical diagram, load power and purpose, observed incidents and equipment already installed. Existing records or consumption profiles help define the assessment.

Current data sheets

Frequently asked questions

Does the same configuration suit backup and power management?

Each use has different priorities. The design must consider required power, duration of use and coordination with the rest of the facility.

Can it be part of a facility with on-site generation?

Integration is assessed against available generation, consumption and the purpose of storage. The assessment defines how they should work together.

Let’s talk